PROCESS CONTROLS

Warehouse Department

wharehouse department
Section Type of control Controlled lots Frequency
- Quality Control At Receipt Of Stators And Rotors All Sample

Mechanical Department

mechanical department
Section Type of control Controlled lots Frequency
Lathe Shafts Dimensions Control All 1 Pc. Every 100 Pcs.
Lathe Control Of The Dimensions Of The Shields/Flanges All 1 Pc. Every 100 Pcs.
Grinding Dimensions Control Of The End Of The Shaft And Bearings Seats All 1 Pc. Every 25 Pcs.
Grinding Control Of Milling Dimensions All 1 Pc. Every 100 Pcs.
Grinding Control Of Rotor Air Gap Dimensions All 1 Pc. Every 25 Pcs.
Grinding Control Of Threads Dimensions All 1 Pc. Every 25 Pcs.
Grinding Control Of The Dimensions Of The Spline Exit All 1 Pc. Every 25 Pcs.

Winding Department

Winding Department
Section Type of control Controlled lots Frequency
Insertion Of Coils Control Of Copper Diameter Section All Sample
Cables Connection Control Of Heads Dimensions All 1 Pc. Per Lot
Cables Connection Ohmic Resistance Control Of Wound Stator All -
Cables Connection Control Of Dieletric Rigidity (Mass) 1900 V All 100% Production
Cables Connection Surge Control (Short Turn) 1600 V All 100% Production
Cables Connection Control Of Sense Of Rotation All 100% Production
Insertion Of Wound Stator In The Housing Control Diameter Dimension Of The Housing All Sample
Insertion Of Wound Stator In The Housing Lenght Control Of Housing Stroke All Sample
Impregnation Impregnation Control Of Wound Stator All 100% Production

Assemblying Department

assemblyng department
Section Type of control Controlled lots Frequency
End Line Control Of Bearings Insertion All 100% Production
End Line Cable Control Of Motor With Terminal Board All 100% Production
End Line Cable Control Of Single Phase Motor Without Terminal Board All 100% Production
End Lne Control Of Sense Of Rotation All 100% Production
End Line Control Of Spline Protrusion All 100% Production
End Line Control Of Nameplate Data All 100% Production
End Line Control Of Dieletric Rigidity (Mass) 1900 V All 100% Production
End Line Value Control Of Absorbed Current No Load (Consumption Test) All 100% Production

Testing Room

testing room
Section Type of control Controlled lots Frequency
- Test With Blocked Rotor Sample Sample
- No Load Test Sample Sample
- Full Load Test Sample Sample
- Warming Test Sample Sample
- Max Moment Sample Sample
- Rise Test Sample Sample
- Max Torque Test Sample Sample